|
News | Products | Store | About us | Contact us |
Atmoweld Exporter for 3D Studio Max (LightWave File Object Export): Errors & Warning CodesLightWave Object File Exporter. Error and Warning Codes. System ErrorsError Code 100: Not enough memory.Insufficient memory to begin the export. Error Code 101: No Geometry.The scene does not contain geometry which can be exported. Error Code 102: Fails to build material table.Atmoweld Exporter Cannot gather the table of materials. Error Code 103: Fails to export material list.Atmoweld Exporter cannot export material list. Error Code 104: Fails to save LightWave Object.Atmoweld Exporter fails to save Lightwave Object File (LWO). Error Code 105: Fails to load config.Configuration file cannot be loaded. Error Code 106: Fails to save config file.Configuration file cannot be saved. Material Related ErrorsError Code 200: Cannot Export material. Incompatible Material Class.Material cannot be exported. Error Code 201: Invalid MultiMaterial.MultiMaterial cannot be exported. Error Code 202: Sub maps are not supported.SubMaps cannot be saved. SubMaps are not supported in Atmoweld Exporter. Error Code 203: Facemap not allowed.Facemap cannot be saved properly . Not supported. More information: "Export Materials". Error Code 204: Incompatible material.Incompatible material is detected. Error Code 205: Fails to invoke duplicate material names modification.Exporter fails to invoke duplicate material names modification. Mesh Related ErrorsError Code 300: Invalid Material Info.Mesh not linked with the material.
Symptom: material is not assigned. Error Code 301: Invalid Material.Mesh linked with the incorrect material. Error Code 302: Fails to init mesh table.Mesh table cannot be created. Error Code 303: Invalid Node Object.Mesh (node) cannot be saved. Error Code 304: No Geometry Vertices.Mesh does not contain geometry vertices. Export is not possible. Error Code 305: No Faces.Mesh does not contain faces. Export is not possible. Error Code 306: Fails to export mesh.Mesh cannot be exported. Limit Related ErrorsError Code 400: Faces limit has been reached.Faces limit has been reached. Error Code 401: Geometry vertices limit has been reached.Geometry vertices limit has been reached. Error Code 402: Texture vertices limit has been reached.Texture vertices limit has been reached. Error Code 403: Layers limit has been reached.Layers limit has been reached. Error Code 405: Material limit has been reached.Material limit has been reached. Error Code 406: PTAG limit has been reached.PTAG limit has been reached. Units Related ErrorsError Code 500: Invalid Master Units.It is detected with checking Master Units that the model is made in the units of the measurements, which do not correspond to the given ones with checking Master Units Validation. More Information: "Master Units". Texture Related ErrorsError Code 600: Invalid texture name.Invalid texture name. Error Code 601: Texture file found.Texture file found. Error Code 602: Incompatable texture.Texture is not compatible with LightWave. Example: DDS file. Error Code 603: Cannot assign relative path for texture.Texture path cannot be relative (relative to Content Directory). More information: "Content Directory". Error Code 604: Invalid absolute texture path.Invalid absolute texture path. Error Code 605: Invalid Map.Map contains the information, incompatible with Atmoweld Exporter. Error Code 606: Unknown map type.Unknown map type. Error Code 607: Invalid Wrap Info.Invalid Wrap Info. Error Code 608: Sub maps are not supported.SubMaps are not supported. Error Code 609: Invalid Standart Texture Out Generator.Invalid Standart Texture Out Generator. More information: "Export Materials". Error Code 610: Invalid UVGenerator.Invalid UVGenerator. Error Code 611: Non-'Bitmap' Texture Class detected.Textural class must be Bitmap. Name Convention ErrorsError Code 700: Invalid mesh name.Mesh name do not correspond to Name Convention. Error Code 701: Invalid material name.Material name do not correspond to Name Convention. Error Code 702: Invalid texture name.Texture name do not correspond to Name Convention. Error Code 703: Invalid LightWave Object file name.LightWave Object File name not correspond to Name Convention. WarningsWarning Code 100: Degenerated faces detected (validation by faces).Degenerated Faces are detected. More Information: "Degenerated Faces". Warning Code 101: Degenerated faces detected (validation by vertices).Degenerated Faces are detected. More Information: "Degenerated Faces". Warning Code 102: Isolated Mesh Vertices need to be erased.Isolated Mesh Vertices are detected. Isolated Mesh Vertices need to be erased. Warning Code 103: Isolated UVMap Vertices need to be erased.Isolated UVMap Vertices are detected. Isolated UVMap Vertices need to be erased. Warning Code 104: Intersections.Intersections between the face (inside one mesh) are detected. Warning Code 105: Invalid Material.Invalid Material. Material is not supported in Atmoweld Exporter. Warning Code 106: Camera ignoredCamera cannot be exported. Warning Code 107: Light ignoredLight cannot be exported. Warning Code 108: Shape ignoredShape cannot be exported. Warning Code 109: Helper ignoredHelper cannot be exported. Warning Code 110: Found material name duplicates. Duplicates have been renamed.Exporter fixes material name duplicates automatically. |
|
| Copyright © 2000 - 2007 by Firevector Technologies. Legal Notices. | |